Error code Description Action 0010002 Microprocessor not supported. If an action step is preceded by "(Trained service technician only)", that step must be performed only by a trained service technician. Note: The server will not power-on when the microprocessor in socket 1 or 2 is not installed in the server. (Trained service technician only) Toggle the switch block (SW4), bit 3 You might have to use a pen or the end of a straightened paper clip to press the button. this contact form

A hard disk drive has failed or is missing. A failing fan can cause the TEMP LED to be lit. Power supply 1 or 2 has failed. FAN A fan has failed, is operating too slowly, or has been removed. http://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.ibm.sysx.7945.doc/r_light_path_diagnostics_leds.html

Ibm X3650 Dasd Error Light

Table 1. Update the IMM firmware to the latest level (see Updating the firmware). 3808003 Error retrieving system configuration from IMM Shut down the system and remove the power cords from the server; Note: The system service label on the underside of the cover also provides information about the location of the light path diagnostics LEDs.

Reconnect the server to the power source, then turn on the server. 305000A RTC date/time is incorrect Adjust the date and time settings in the Setup utility, and then restart the If the error remains, replace the following components in the order listed, restarting the server after each: Replace the hard disk drive (see Removing a hot-swap hard disk drive for more If the failure remains, go to the "Before you call IBM Service" website for additional troubleshooting information. Light Path Diagnostics Checkpoint Codes If the 12 V channel E error LED is lit, complete the following steps: Turn off the server and disconnect the power from the server.

PS A power supply has failed. Ibm Light Path Diagnostics Make sure that the room temperature is not too high. Make sure that the server is attached to a reliable power source. http://www.ibm.com/support/knowledgecenter/ST5Q4U/com.ibm.storwize.v7000.unified.143.doc/bb1gt_r_lightpathdiapan.html Make sure that the DIMMs are installed in the correct sequence (see Installing a DIMM for more information). (Trained service technician only) Replace the microprocessor that controls the failing DIMMs. (Trained

Then pull down on the panel so that you can view the light path diagnostics panel information. Ibm Light Path Diagnostics Checkpoint Codes See System-board switches and jumpers for the location of the SW4 switch block on the system board. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server. Switch the bank back to the primary bank. (Trained service technician only) Replace the system board. 3818007 CRTM update capsule signature invalid Run the Setup utility, select Load Default Settings, and

  • This is the accepted answer.
  • By viewing the LEDs in a particular order, you can often identify the source of the error.
  • If the OVER SPEC LED on the light path diagnostics panel is lit, or any of the six 12 V channel error LEDs (A, B, C, D, E, or AUX) on
  • Replace the following components one at a time, in the following order, restarting the server after each one: Battery (Trained service technician only) System board. 2011001 PCI-X SERR Check the riser-card
  • If the problem is related to a DIMM, replace the failing DIMM. (Trained service technician only) If the problem occurs on the same DIMM connector, check the DIMM connector.
  • Remove the server cover and look inside the server for lit LEDs.
  • The display does not provide error codes or suggest components to be replaced.
  • At the Light Path Diagnostics shows PS Error 9:F.
  • If the CNFG LED is lit, the system issues an invalid microprocessor configuration error.
  • SystemAdmin 110000D4XK ‏2012-11-07T04:19:19Z Also I don't have video.

Ibm Light Path Diagnostics

Harddisk have born failure. 2. https://www.ibm.com/developerworks/community/forums/thread.jspa?threadID=396558 If the failure remains, go tothe "Before you call IBM Service" website for additional troubleshooting information. Ibm X3650 Dasd Error Light This is the accepted answer. Ibm X3650 M3 Checkpoint Code Display 9f The following illustration shows the light path diagnostics panel:Figure 2.

If the CNFG LED is not lit, the system might detect a memory error. weblink Operator information panel To view the light path diagnostics panel, slide the blue release latch on the operator panel to the left. Reseat the hard disk drive backplane. Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server. Ibm Checkpoint Code 9f

By placing the system-error LED indicator in Remind mode, you acknowledge that you are aware of the last failure but will not take immediate action to correct the problem. Reseat the DIMMs and restart the server. Make sure that the microprocessors are compatible with each other. http://bookmarq.net/checkpoint-code/ibm-error-code-9f.php Run the Setup utility, select Load Default Settings, and save the settings.

The following illustration shows the LEDs on the riser card. Ibm Checkpoint Codes BRD An error has occurred on the system board. This is the accepted answer.

Figure 4.

See "Parts listing" to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). The BRD LED can be lit due to any of the following reasons: Battery Missing PCI riser-card assembly Failed voltage regulator Check the system-error log for information about the error. Check the IMM system event log and the system-error log for information about the error. Ibm Light Path Diagnostics Dasd 9f Remove one of the power supplies to isolate the failed power supply.

Reseat the failing fan, which is indicated by a lit LED near the fan connector on the system board.. This information and the information in Light path diagnostics LEDs can often provide enough information to diagnose the error. Update the firmware on the IMM. his comment is here LED Problem Action None, but the system-error LED is lit.

Update the IMM firmware to the latest level (see Updating the firmware). Remove the server cover and look inside the server for lit LEDs. CNFG A hardware configuration error has occurred. (This LED is used with the MEM and CPU LEDs.) If the CNFG LED and the CPU LED are lit, complete the following steps: