Home > Error Codes > Ibm Hdd Error Codes

Ibm Hdd Error Codes

Contents

A failing fan can cause the TEMP LED to be lit. Replace the following components, one at a time, in the order shown, restarting the blade server each time: I/O expansion card in slot xx - Optional expansion unit (if one is Reseat the storage drives. If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit. Check This Out

Save and exit. If the green activity LED is flashing and the amber status LED is flashing slowly, the drive is recognized by the controller and is rebuilding. See error code 00151500 to determine which DIMM to reseat. Replace the SAS expander card. http://www.bioscentral.com/misc/ibmdiag.htm

Ibm Error Codes

DASD A hard disk drive error has occurred. An amber hard disk drive status LED does not accurately represent the actual state of the associated drive. Check the power-supply that has an lit amber LED (see Power-supply LEDs). Check the LEDs on the PCI slots to identify the component that is causing the error.

  1. Replace the failed hard disk drive.
  2. Complete the following steps to correct the problem: Update the server firmware to the latest level (see Updating the firmware).
  3. Test the hard drive for errors.

Then run BIOS Setup Utility to reset the time and date. Run the Configuration/Setup Utility program Battery Failing device System board 163 (Real-time clock error) Run the Configuration/Setup Utility program Battery System board 164 (Memory configuration changed) Run the Configuration/Setup Utility program Turn on the server and observe the activity of the hard disk drive LEDs. 162 Configuration Error Ibm Server X3650 Review the storage subsystem logs for indications of problems within the storage subsystem, such as backplane or cable problems.

Replace the following components one at a time, in the order shown, restarting the blade server each time: Storage drive - Depending on your storage-drive configuration, replace one of the following:Fixed-storage Select Boot and then press the Enter key. Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit. (Trained service technician only) System-board assembly - See Removing the system-board http://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.ibm.sysx.7944.doc/r_hdd_problems.html If the activity of the LEDs changes, return to step 2.

Replace the backplane. Ibm Checkpoint Code 9f Run the SAS Attached Disk diagnostic test - See Dynamic system analysis diagnostic programs and messages. Go to http://www.ibm.com/systems/support/. 012981xx Unable to apply the Microcode Update for Processor xx Make sure that the microprocessor is supported. Enter BIOS Setup and Load Setup Defaults.Run the BIOS Setup Utility and Load Setup Defaults0185Bad startup sequence settings.

Ibm Checkpoint Codes

Observe the associated green hard disk drive activity LED and the amber status LED: If the green activity LED is flashing and the amber status LED is not lit, the drive get redirected here Your feedback helps to improve this site. Ibm Error Codes Replace the following components one at a time, in the order shown, restarting the blade server each time: Failed I/O expansion card - See Removing an I/O expansion card andInstalling an How Many Digits Are In A Mac Address? See Solving shared BladeCenter resource problems. (Trained service technician only) Replace the system-board assembly - See Removing the system-board assembly and Installing the system-board assembly. 1200 Processor machine check. (Trained service

If there is no disk drive error log error log, replace the affected backplane. his comment is here Detected on Processor bus. (Trained service technician only) Reseat the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink. If the CNFG LED is lit, then an invalid microprocessor configuration has occurred. System board 0271Date and time error. What Dos Command Do You Use To Erase A Hard Drive And Make It Bootable?

Run the Configuration/Setup Utility program and make sure that interrupt resource settings are correct. For more information, see Hard disk drive problems. Make sure that the hard disk drive is recognized by the adapter (the green hard disk drive activity LED is flashing). this contact form The shadow RAM failure at offset nnnn.System board0231System RAM error.

Noisy drives are not always defective. Parity Error Message Note: Check the system-event log and the IMM event log for additional information before you replace a FRU. System board 01CAMore than one Wireless LAN devices are found.

Your feedback helps to improve this site.

Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. Hot-swap storage drive - See Removing a hot-swap storage drive and Installing a hot-swap storage drive. If a password prompt appears, type the correct password. Hdd Controller Failure If the failure remains, go to the "Before you call IBM Service" website for additional troubleshooting information.

Thanks to Mike Rose for erors 129 and 229! Therefore, I hope to provide this to all those other technicians out there who get the opportunity to work on one of these. If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. http://bookmarq.net/error-codes/ibm-was-error-codes.php Move the hard disk drives to different bays to determine if the drive or the backplane is not functioning.

The TEMP LED might also be lit. VRM Reserved.   Parent topic: Light path diagnostics Select a country/region: United States IBM® Site map Search Select a language Translate this page Return to English Portuguese French German Italian Japanese Replace a DIMM - See Removing a memory module and Installing a memory module. Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit. (Trained service technician only) System-board assembly - See Removing the system-board

Boot from Recovery CD and perform full recovery from it. If the MEM LED and the CNFG LED are lit, complete the following steps: Check the system-event log in the Setup utility or IMM error messages. If the activity of the LEDs remains the same, go to step 5. Check the system-event log in the Setup utility or IMM error messages.

If the amber hard disk drive LED and the RAID controller software do not indicate the same status for the drive, complete the following steps: Turn off the server. The BIOS setup Utility menu will be displayed.