Home > I O > I O Error Reading Data Mainframe

I O Error Reading Data Mainframe

You should review any FFDCs from the time frame and also review webserver or load balancer logs to see if errors were returned. After an attempt to rerun the script, it was successful. THIS CAN BE EITHER THE HEADER ADDRESS AND/OR THE AREA ADDRESS. RT016 Too many device files open. http://bookmarq.net/i-o/i-o-data-error-lotus-notes.php

If most members in the PDS were created from ISPF and have member stats, then that would also narrow it down to members without member stats. S013 - 48 - AN OPEN MACRO WAS ISSUED FOR A SEQUENTIAL DATASET USING THE QUEUED ACCESS TECHNIQUE, BUT THE BUFFER CONTROL BLOCK ADDRESS WAS ZERO. A CONFLICT EXISTS AMONG LABEL PARAMETERS ON THE DD STATEMENT, AND DCBRECFM, DCBOPTCD, DCBBUFOF, AND DCBUSASI GIVE THE APPEARANCEOF MIXED USASI AND EBCDIC ATTRIBUTES TO THE DATASET; OR OPTCD=Q WAS SPECIFIED Regards, - Amit._________________I did not fail; I have found 10,000 ways that would not work - Albert Einstein.

S02B - A USER EXIT ROUTINE ISSUED A RETURN CODE GREATER THAN THAT SPECIFIED IN THE &MAXRC PARAMETER OF THE $EXIT### MACRO. Faced same problem and solution worked. For example, if you are writing a file to disk and the disk runs out of space, the ANSI'74 file status would be "30", which translates into a "Permanent error - S013 - 40 - A SEQUENTIAL OR DIRECT DATASET WAS OPENED FOR INPUT, BUT THE BUFFER CONTROL BLOCK ADDRESS WAS 0.

SUBSEQUENT DEBCHKS ISSUED TO VERIFY OR DELETE THAT DEB POINTER MUST EITHER SPECIFY THE SAME AM VALUE OR OMIT THE OPERAND. RT039 File not compatible. S213 - 50 - OPEN DETECTED AN ERROR RETURN CODE FROM AN SMS SERVICE WHILE PROCESSING A PDSE. IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S171 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S171-RC)POSSIBLE CAUSE:INPUT PARAMETER ERROR IN VIRTUAL SUBAREA LIST (VSL):- VSL NOT

S030 - DURING A BISAM OR QISAM OPEN DCBMACRF DID NOT INDICATE A VALID MODE OF OPERATION. S013 - CC - SETPRT PROCESSING FAILED TO SET UP THE DEVICE DURING AN OPEN FOR THE IBM 3800 PRINTING SUBSYSTEM. Honestly, it is quite unlikely anyone on this list can get you through this problem - you will need to seek technical guidance and assistance, possibly your SAS admin, to analyze internet S100 - I/O INTERBLOCK GAP DETECTED WHEN WRITING RECORD S101 - DURING EXECUTION OF A WAIT MACRO, THE PROBLEM PROGRAM SPECIFIED MORE EVENTS THAN THERE WERE ECBS.

A WRITE MACRO WAS ISSUED CAUSING A SECONDARY EXTENT TO BE OBTAINED. S002 - 94 - INCORRECT ATTEMPT TO CREATE A PDSE MEMBER SINCE THE MAXIMUM NUMBER OF MEMBERS HAVE ALREADY BEEN CREATED. S213 - 68 - AN OPEN FOR A PDSE WAS ISSUED WITH RECFM=FB AND LRECL=0. THE VOLUME SERIAL NUMBERS ON THE DD STATEMENT WERE NOT SPECIFIED IN THE SAME ORDER THAT THE DATASET WAS CREATED.

But the script (hitting the I/O error) is a matured script i.e. Discover More DURING THE EXECUTION OF OPEN IT WAS DETECTED THAT THE BLOCKSIZE WAS LARGER THAN THE PRIMARY EXTENT. U2000 - I/OR ERROR. THE RECORD LENGTH IS GREATER THAN THE BLOCKSIZE SPECIFIED IN THE DCB.

S013 - 74 - AN OPEN MACRO WAS ISSUED FOR AN OPTICAL CHARACTER READER DATASET, BUT THE OPEN OPTION DID NOT SPECIFY INPUT. weblink try to put the code and the FULL error line. Thank you Back to top Display posts from previous: All Posts1 Day7 Days2 Weeks1 Month3 Months6 Months1 YearOldest FirstNewest First MVSFORUMS.com Forum Index -> Problem Determination All times are GMT RT041 Corrupt index file.

  1. THE SYSTEM DETERMINED THAT A BUFFER POOL EXISTED FOR THIS DATASET AND MADE THE APPROPIATE TEST SHOWN BELOW WITH UNSATISFACTORY RESULTS:- IF THE DATA WAS TO BE SENT DIRECTLY TO A
  2. RT066 Attempt to add duplicate record key to indexed file.
  3. Question by Paul_McKenna_WASCET_L2 (354) | Jul 28, 2015 at 10:57 AM bpmssoprocess_inspector Using BPM 8.0.1.3, I try to bring up the Process Inspector on my browser.
  4. S222 - JOB CANCELLED S233 - INVALID PARAMETERS HAVE BEEN PASSED TO SVC DUMP.
  5. S053 - A PROGRAM MADE A PC/AUTH REQUEST BUT AN ERROR PREVENTED NORMAL COMPLETION.
  6. NOT ENOUGH REAL STORAGE AVAILABLE TO BACK A MINIMUM NUMBER OF VSM CELLS (IN LSQA) DURING LOCAL CELL POOL EXPANSION.
  7. S07C - SUPERVISOR CONTROL RECOVERY HAS DETECTED AN ERROR WHICH REQUIRES THAT THE CURRENT TASK BE TERMINATED OR THAT THE CURRENT ADDRESS SPACE BE TERMINATED.
  8. A WRITE MACRO WAS ISSUED TO WRITE OUT A BLOCK LARGER THAN THE PRIMARY EXTENT ON THE PREALLOCATED DATASET.
  9. THIS INSTRUCTION IS NOT VALID IN OS/VS2 (SINCE RELEASE 2).

NOT ENOUGH REAL STORAGE AVAILABLE TO BACK A MINIMUM NUMBER OF VSM CELLS (IN LSQA) DURING LOCAL CELL POOL EXPANSION. IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S178 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S178-RC)** S178 - 04 - NOT ENOUGH REAL STORAGE FOR SPACE EITHER NO SYNAD ROUTINE WAS PROVIDED TO HANDLE THE ERROR, OR DCB=EROPT=ABE WAS SPECIFIED OR DEFAULTED.IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S001 OPERAND FOR MORE navigate here Mohd Fazli Baharuddin asked Jun 24, 2010 | Replies (9) Hi, I'm totally new to SAS.

SEGMENT MODE IS IMPLIED. THE ROUTINE WAS GIVEN CONTROL FOLLOWING EXECUTION OF A BSAM CHECK MACRO INSTRUCTION. A DEB WHOSE ADDRESS IS NOT IN THE DEB TABLE CANNOT BE VERIFIED, DELETED, OR PURGED S16E - 08 - INVALID TYPE SPECIFIED (MACRO NOT ISSUED).

has been run many times before with no change in logic.

THE ERROR OCURRED BECAUSE THE I/O MACRO INSTRUCTIONS FOR A 3525-ASSOCIATED DATA SET WERE NOT EXECUTED IN THE PROPER SEQUENCE.- IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN CHECK REGISTER 0:- 20 - ERROR CONVERTING TTR.- 24 - BLOCK IS OUTSIDE OF THE MODULE.- 28 - AN ADCON LOCATION IS INVALID. S306 - 34 - THE USER ATTEMPTED TO USE A PROGRAM WHILE A PROGRAM-ACCESSED DATA SET WAS OPEN. S206 - THE ADDRESS OF THE PARAMETER LIST, OR ONE OF THE PARAMETERS PASSED TO A LINK, LOAD, XCTL, OR DELETE MACRO WAS INVALID.

S0F8 - 1C - THE SVC ISSUER WAS NOT AUTHORIZED FOR SVC MICROCODE ASSIST. The reason code indicates which subcomponent or process was active when the exception was detected. Status Key 1 Status Key 2 See Code Description 9 0 9/143 REWRITE/DELETE not after successful READ 9/147 Wrong open or access mode for READ/ START. 9/148 Wrong open or access his comment is here S30A - 1C - ZERO LENGTH WAS NOT SPECIFIED ON A SUBPOOL FREEMAIN.

RT001 Insufficient buffer space. A WRITE MACRO WAS ISSUED FOR A RECORD LARGER THAN THE TRACK CAPACITY, AND THE RECORD FORMAT DOES NOT USE THE TRACK OVERFLOW FEATURE.