But 550 server had fsp as onboard. DEFERRED On model 575 and 59x systems in which an IBM High Performance Switch (HPS) is installed, fixed a problem that was causing an invalid high performance switch adapter failure to Ensure that the HMC is not network-connected to an HMC with call home enabled prior to beginning the firmware installation. To determine if a service pack is disruptive, refer to section 3.0 of this document. this contact form

Note: The concurrent levels of system firmware may, on occasion, contain fixes that are known as deferred. Join this group Popular White Paper On This Topic A Beginner's Guide to VoIP 18Replies Best Answer 1 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes On systems with a redundant service processor, a problem was fixed that caused the system to crash (with SRC B18187E3 being logged) when an administrative failover to the secondary service processor Yothin Wanmek replied Feb 4, 2012 I've had to reseat the battery mainboard on 9113-550 server and retry boot server again to normally. http://unix.ittoolbox.com/groups/technical-functional/ibm-aix-l/server-p-550-9113550-hang-on-b181f22a-2946501

B150f22a

A problem was fixed that caused error code HSCL1400 to be generated when a redundant service processor was installed with firmware release SF230 or earlier. Added support for new models: 9131-52A, 9111-285, 9133-55A, 9115-505. Added support for modifying the number of On/Off CoD activations during the active period.

  • SF230_150_120 Impact: Serviceability Severity: Special Attention Attention: An IPL is required to activate a deferred fix, the system must be powered off via the HMC, (i.e.
  • All times are GMT-6.
  • A problem was fixed that prevented the "identify" LEDs from being toggled correctly on some enclosures.
  • Due to hardware prerequisites which must be verified prior to performing a firmware upgrade from release level SF230_xxx to higher release levels, customers are advised not to perform this upgrade on
  • Full details are available here.
  • In a system with redundant service processors, a problem was fixed that prevented the IP information from the secondary service processor (that was deconfigured or not working) from being displayed by

A problem was fixed on p5 systems (that have a graphics adapter and a USB adapter) that caused the firmware's console selection to be lost when firmware level SF240_202_201 was installed. System firmware changes that affect all p5 and i5 systems: The firmware was updated to include additional resources on the Advanced System Management Interface (ASMI) deconfiguration menu for the celogin user. sathish subramaniam replied Aug 24, 2009 It is firmware related issue. Fixed a problem that caused commands involving LEDs to time out on large, heavily configured systems.

This change only affects systems participating in an HSL Opticonnect cluster environment. C7004091 By furnishing this document, IBM grants no licenses to any related patents or copyrights. IBM would make that call. http://www.ibm.com/support/knowledgecenter/POWER5/ipha6_p5/b1xxa.htm A problem was fixed that was preventing systems and partitions with multiple fiber channel adapters from booting.

Bulk power code BP240_197, or a higher level, must also be installed to fully implement this fix. Fixed a problem that caused a service processor dump or a platform dump and SRC B1817201 or B7004400. Support for Power5+ processors on the pSeries models 510, 510Q, 520, 520Q, and 570. B181F22A Error Code in AIX P5 pbentil asked Feb 2, 2012 | Replies (6) Can you help me?

C7004091

Call home should be enabled again at the end of the firmware installation. http://www.ibm.com/support/docview.wss?uid=nas2MB01606 This thread ... 4. B150f22a SF230_147_120 Impact: Serviceability Severity: Special Attention Fixed a problem that caused system processors to get into a locked state. Error P5er System Preventing Process Mcafee A problem was fixed that was causing SRC B1xxE500 (with SRC word 8 equal to DD02) when processor runtime diagnostics were called during a dump.

HMC state=Power OFF) and then powered back on. A problem was fixed that caused the service processor to perform a reset/reload too frequently, which caused too many dump files to be generated. marate_rao replied Feb 2, 2012 Hi, This could be a problem of Hardware. A problem was fixed that caused an IOP-less i5/OS partition with a large amount of memory and a small logical memory block (LMB) size to fail to boot. C1802000

For the model 59x systems, the FRU list for MCM and memory card VPD access errors was updated to include the MUX card. System firmware changes that affect HMC-controlled servers and clustered systems: HIPER: A problem was fixed that caused the service processor's /tmp filesystem to became full. This could result in a system checkstop. On model 590 and 595 systems, fixed a problem that was causing DDR II memory cards in slots C10 and C12 to fail the memory test during a slow-mode boot.

The firmware has been changed so that the I/O paths are no longer deconfigured under these circumstances. These deferred fixes can be installed concurrently, but will not be activated until the next IPL. The failure is due to a timing condition in the SF230_120 and SF230_126 firmware (look for an error log entry with SRC B181873C).

Navigate down to the options under "System Configuration" followed by "Hardware Deconfiguration".

Clothes arithmetic Why don't major research institutions systematically publish their subscription fees to scientific journals? New processor feature code / CCIN code combination are supported. How do I track down what this means? Any trademarks and product or brand names referenced in this document are the property of their respective owners.

For example, 01SF235_250_120 and 01SF240_250_200 are different service packs. For information about the recovery procedure if the system is in half genesis mode, call you next level of support. 2.2 Cautions Do not attempt to backlevel firmware from any given Database Baselines Factorial digit sum How to start building a regression model when the most strongly associated predictor is binary cat gives different error when opening non-existing file Is the Tate-Shafarevich A problem was fixed that might have caused the wrong memory DIMM to be called out if a memory failure occurs.

The firmware was updated to add the system VPD card and service processor to the Advanced System Management Interface (ASMI) deconfiguration menu under the celogin. If the inband firmware installation fails on power down of the service partition, in some cases the next attempt will fail. The service processor is not able to place a "call home" through a modem. This function supports nondisruptive system firmware service packs to be applied to the system concurrently (without requiring an IPL to activate changes).

Licensed Internal Code update will cause loss of service processor redundancy. DEFERRED and HIPER: Additional hardware initialization settings were changed to prevent system hangs with B7xx406E reference code. On systems that are not managed by an HMC, a problem was fixed that caused the temporary (T) side of the flash to report its level as "unknown", and SRC B181300A a fan died somewhere) or utterly cryptic ("there's no detailed description for error code XXXXX").

What to do when you are asked to perform an official review for a journal of a manuscript written by your supervisor? The failure is due to a timing condition in the SF230_120 and SF230_126 firmware (look for an error log with the SRC B181873C). A problem was fixed that, under some circumstances, prevented remote support from gathering information about partitions that are running. On a partition booting i5/OS, a problem was fixed that prevented the partition from booting if the partition had a large amount of memory (greater than approximately 200 GB) allocated to